Entering the license key
Note
You need to insert the memory card into the Control Unit before entering the license key.
With the STARTER commissioning tool, the ASCII characters are not entered in code,
but the letters and numbers in the license key can be input directly as they appear on the
license certificate.
In this case, the ASCII coding is processed by STARTER in the background.
Example of a license key:
E1MQ-4BEA = 69 49 77 81 45 52 66 69 65 dec (ASCII characters)
Procedure for entering a license key (see example):
p9920[0] = E 1st character
...
p9920[8] = A 9th character
Note
When changing p9920[x] to the value 0, all of the following indices are also set to 0.
After the license key has been entered, it has to be activated as follows:
● p9921 = 1 Licensing, activate license key
Entering the license key with BOP20
If you use the BOP20 to enter the license key, you will need to use the ASCII code for the
key (see above for an example). In the table below, you can enter the characters in the
license key and the corresponding decimal numbers.
Table 10- 6
License key table
Letter/numb
er
decimal
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
The parameter is automatically reset to 0
Basic information about the drive system
10.8 Licensing