Siemens Sinamics S110 Function Manual page 575

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

MTn_ZS_F and MTn_ZS_S
Display of the measuring time determined
The measuring time is specified as a 16-bit value with a resolution of 0.25 μs.
Features of the central probe
● The time stamps from probes in more than one drive can be transferred simultaneously in
● The time in the controller and drive unit is synchronized via CU_STW1 and the
● A higher-level controller can then use the time stamp to determine the actual position
● The system outputs a message if the measuring time determination function in the probe
Example: central probe
Assumptions for the example:
● Determination of the time stamp MT1_ZS_S by evaluating the rising edge of probe 1
● Determination of the time stamp MT2_ZS_S and MT2_ZS_F by evaluating the rising and
● Probe 1 on DI/DO 9 of the Control Unit (p0680[0] = 1)
● Probe 2 on DI/DO 10 of the Control Unit (p0680[1] = 2)
● Manufacturer-specific telegram p0922 = 391 is set.
Function Manual
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
a single telegram.
CU_ZSW1.
Note: The controller must support time synchronization!
value of more than one drive.
is already in use (see also p0488, p0489, and p0580).
falling edge of probe 2
Figure 9-14
Sequence chart for central probe example
9.2 Communication according to PROFIdrive
Communication
573

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents