Basic information about the drive system
10.3 Working with the memory card
10.3.1

Using parameter data sets

Parameter backup
There are several ways of copying parameter data sets from non-volatile memory to the
memory card:
● Automatic backup of parameters to the memory card when the system is switched off/on:
666
Memory card empty?
Yes
Has parameter set
with index 0 been
backed up in the ROM
of the CU305?
Yes
Insert memory card
in CU305
Switch SINAMICS
S110
off and on
again
Parameter backup
with index 0 is
saved to memory
card
Log memory card
off (p9400 = 2)
and remove it
from CU305
Figure 10-4
Parameter backup
Delete all data on
memory card
or provide an
No
empty
card
Copy parameter
set
No
index 0 from RAM
to ROM
Function Manual, 01/2011, 6SL3097-4AB10-0BP3