Profinet: Address Parameters; Hardware Setup; Structuring Cu305 With Profinet - Siemens Sinamics S110 Function Manual

Hide thumbs Also See for Sinamics S110:
Table of Contents

Advertisement

Communication
9.4 Communication via PROFINET IO
9.4.1.5

PROFINET: Address parameters

Overview of important parameters (see SINAMICS S110 List Manual)
For integrated PROFINET interface
● p8920[0...239] PN Name of station
● p8921[0...3] PN IP Address of station
● p8922[0...3] PN Default gateway of station
● p8923[0...3] PN Subnet mask of station
● p8925 PN interface configuration
● p8929 PN Number of remote controllers
● r8930[0...239] PN Name of station active
● r8931[0...3] PN IP Address of station active
● r8932[0...3] PN Default gateway of station active
● r8933[0...3] PN Subnet mask of station active
● r8935[0...5] PN MAC address of station
● r8936[0...1] PN State of the cyclical connections
● r8937[0...5] PN Diagnostics
9.4.2

Hardware setup

9.4.2.1

Structuring CU305 with PROFINET

PROFINET interface for CU305 PN
A PROFINET interface with 2 ports is integrated in the CU305 PN module.
Note
The ports must not be interconnected in such a way that a ring topology is created.
References
● The PROFINET interface on the CU305 PN unit is described in the document: SINAMICS
622
S110 Manual.
Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Function Manual