Configuring alarms
Alarm Priority
If the above Inherit alarm priority from event setting is not enabled, this parameter selects
the priority of the reason. Valid values are 0 to 9.
Alarm Priority is dependent on the event being logged by Entity
Selecting this setting makes the priority conditional on which system entity triggered the
event, such as Ethernet, and enables the following two configuration options:
Entity
A list of the system entities.
All
Selects all of the system entities.
Instance
Selecting this radio button enable a text entry box that allows the user to enter the instance of
the selected entity.
Priority only applies to
A set of checkboxes, each checkbox controlling whether the priority is applied to that interface
instance. So for example, to apply the priority to PPP interface 1, click on PPP 1 checkbox.
Store a snapshot of the Traffic Analyser trace on the log drive
Causes a snapshot of the analyser trace to be stored on the USB flash drive
If this event creates an Email alarm
Attach a snapshot of the Traffic Analyser trace
Causes a snapshot of the analyser trace to be attached to the email.
After this event
Leave the Analyser trace
Leaves the analyser trace unchanged.
Freeze the Analyser trace
Causes the analyser to be frozen, such as no more logging will take place until the email has
been sent.
Delete the Analyser trace
Causes the analyser trace to be deleted once the email has been sent.
Attach a snapshot of the Event Log
Causes the event log to be attached to the email.
After this event
Leave the Event Log
Leaves the event log unchanged.
Delete the Event Log
Deletes the event log after the email has been sent.