Configuring legacy protocols
Option
Description
1
PAD recall character is CTRL-P (ASCII 16, DEL)
32-126
PAD recall character is user defined as specified
2 Echo
Enables or disables local echo of data transmitted during a call. When echo is enabled, you can use X.3
parameter 20 to inhibit echoing certain characters.
Option
0
1
3 Data forwarding characters
Defines which characters cause data to be assembled into a packet and forwarded to the network.
Option
0
1
2
4
8
16
32
64
Combinations of the above sets of characters are possible by adding the respective values together.
For example, to define CR, EXT and EOT as data forwarding characters, set this parameter to 18 (2 +
16). If no forwarding characters are defined the Idle timer delay (parameter 4) should be set to a
suitable value, typically 0.2 seconds.
4 Idle timer delay
Defines a time-out period after which data received from the DTE is assembled into a packet and
forwarded to the network. If the forwarding time-out is disabled, one or more characters should be
selected as data forwarding characters using parameter 3.
Option
Description
0
No data forwarding time-out
1
Data forwarding time-out in 20ths of a second.
Digi TransPort® Routers User Guide
Description
Echo off
Echo on
Description
No data forwarding character
Alphanumeric characters (A-Z, a-z, 0-9)
CR
ESC, BEL, ENQ, ACK
DEL, CAN, DC2
EXT, EOT
HT, LF, VT, FF
Characters of decimal value less than 32
Configure X.25 parameters