Digi TransPort WR11 User Manual page 682

Hide thumbs Also See for TransPort WR11:
Table of Contents

Advertisement

Configuring alarms
After power up, wait s seconds before sending Emails, SNMP traps, SMS or
Syslog messages
The delay, in seconds, after power-up that the router should wait before sending any alert
messages. This is useful when the sending of those items would fail if sent too soon after the
router powers up because the underlying interface to use has not completed initialization.
Include event number in the event log and Email, SNMP traps or Syslog
messages
If enabled, event numbers from the logcodes.txt file are included.
3. Click Apply.
  Command line
Command Instance Parameter Values
event
n
event
n
event
n
event
n
Digi TransPort® Routers User Guide
loglevel
0-9
0 none
1 low
9 high
ev_filter
Comma-
separated list of
event numbers
action_dly
Number of
seconds (such as
60)
incevnums 0, 1
Configure events to trigger alarms
Equivalent web parameter
Only log events with a log priority of at
least n
Do not log the following events.
After power up, wait s seconds before
sending Email, SNMP traps, SMS or Syslog
messages.
Include event number.
682

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents