Digi TransPort WR11 User Manual page 315

Hide thumbs Also See for TransPort WR11:
Table of Contents

Advertisement

Configuring network interfaces
Drop line and call: Configures the router to disconnect the current call, drop the line
n
and return to AT command mode when the DTR signal is de-asserted; this is equivalent
to AT&D2.
Drop call on transition
n
Drop line and call on transition
n
DTR de-bounce time s x 20 milliseconds
The length of time, in multiples of 20 milliseconds, for which the DTR signal must be de-
asserted before the router acts on any options that are set to trigger on loss of this signal.
Enter the desired multiple into the text box. Increasing this value makes the router less
sensitive to "bouncing" of the DTR signal. Conversely, decreasing this value makes the router
more sensitive. The default of 100 milliseconds (5 times 20 milliseconds) is a reasonable value.
Escape Character
The character for the escape sequence. The default is the + symbol (ASCII value 43, 0x2b).
Changing this value has the same effect as changing the S2 register.
Escape Delay s x 20 milliseconds
The required minimum length of the pause in the escape sequence, in multiples of 20
milliseconds. The default is 50 x 20 milliseconds, which means the escape sequence becomes
+++, a pause of 1 second and then AT, to drop back to AT command mode. If a delay of some
other value is required, enter it in the text box.
Forwarding Timeout s x 10 milliseconds
The length of time that the router will wait for more data after receiving at least one octet of
data through the serial port and transmitting it onwards. This timer is reset each time more
data is received. The router will forward data onwards when either the forwarding timer
expires or the input buffer becomes full. This parameter applies to ADAPT, TCPDIAL, TCPPERM
and PANS.
Break Transmit Escape Character c
The character in the escape sequence. The - symbol (ASCII value 45, 0x2d) is a recommended
value. Changing this value has the same effect as changing the S3 register. To use the break
sequence, type - three times, with a 1-second pause either side of the three - characters. When
the Async port detects the following sequence, instead of outputting the three minus
characters (they are removed from the output stream), a BREAK condition is placed on the
Async transmitter for 1 second:
<guar d t i m e 1 sec>- - - <guar d t i m e 1 sec>
3. Click Apply.
  Command line
Command Instance Parameter Values
S0=n
n/a
Digi TransPort® Routers User Guide
n/a
Where n=0-255
Configure serial interfaces
Equivalent web parameter
Answer V.120 call after n rings
315

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents