Inputs And Outputs; Commissioning - Festo MS6-SV-E Operating Instructions Manual

Soft-start/quick exhaust valve
Table of Contents

Advertisement

Available languages

Available languages

MS6-SV-...-E-10V24
6.3

Inputs and outputs

Terminal in
multi-pin plug
socket NECA-...
1
2
3
4
5
6
7
8
9
Tab. 4
Terminal assignment
7

Commissioning

Note
For easier commissioning, we recommend planning a reset button (normally closed) in
the power supply circuit. This simplifies resetting in case of error.
The following description of commissioning is graphically supported by the diagrams on the next pages
(with multi-pin plug socket NECA-S1G9-P9-MP1
S1G9-P9-MP3/MP5
outputs in normal operation (if the "Automatic start" operating mode has been set). The operator's
actions are marked in the diagram by an arrow.
To commission the device, proceed as follows:
1. Apply operating pressure p1.
2. Switch on the operating voltage. The MS6-SV-E automatically tests itself for errors.
• Power LED (green)
– illuminates during self test for around 6 s
– flashes green after successful self test,
Festo – MS6-SV-...-E-10V24 – 1310b English
I/O
Allocation
EN1
Enable signal 1 (static or
dynamic)
EN2
Enable signal 2 (static or
dynamic)
13
Signal contact, NO
14
A5
Contact for "Automatic
start" operating mode
S34
Contact for "Automatic
start" or "Monitored
start" operating mode
+L1
Operating voltage
M
GND
Fig. 22). The diagrams show the switching characteristics of the inputs and
Input 0 V/24 V
(EN 61131-2 type 2)
Input 0 V/24 V
(EN 61131-2 type 2)
Potential-free
contact
(semiconductor
relay),
Max. 120 mA
Max. 60 V DC
Input 0 V/24 V
(EN 61131-2 type 2)
+24 V DC ±10 %
Fig. 20; with multi-pin plug socket NECA-
Section 4.3
"Connection
examples"
Section 4.4
"Signal contact"
Section 4.1 and
4.3
63