I/O Signal Connections; Names And Functions For Multi-Winding Drive Unit I/O Signals (Cn1) - YASKAWA Sigma-V Series User Manual

Ac servo drives for use with large-capacity models design and maintenance, multi-winding drive unit rotational motor, mechatrolink-ii communications references, servopack, converter, servomotor
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

3 Wiring and Connection

3.3.1 Names and Functions for Multi-Winding Drive Unit I/O Signals (CN1)

3.3

I/O Signal Connections

This section describes the names and functions of I/O signals (CN1) on the multi-winding drive unit and
SERVOPACKs. Also connection examples are provided for different control methods.
3.3.1

Names and Functions for Multi-Winding Drive Unit I/O Signals (CN1)

The following tables give the names and functions of the I/O signals (CN1) on the multi-winding drive unit.
(1) Input Signals
Signal
P-OT
(/SI2)
N-OT
(/SI3)
/DEC
(/SI1)
EXT1,
/EXT1
EXT2,
/EXT2
EXT3,
/EXT3
/SI0
/SI4
/SI5
/SI6
+24VIN
BAT (+)
BAT (-)
/P-CL
/N-CL
/DBANS
Note 1. The allocation of the input signals (/SI0 to /SI6) can be changed. For details, refer to 3.4.1 Input Signal Alloca-
2. If the forward run prohibited/reverse run prohibited function is used, the servo drive is stopped by software con-
3-16
Pin No.
Name
Forward run
42
prohibited,
43
Reverse run
prohibited
Homing deceleration
41
switch signal
7, 8
External latch signal 1
11, 12
External latch signal 2
14, 15
External latch signal 3
40
44
General-purpose input
signal
45
46
Control power supply
47
for sequence signal
21
Battery (+) input signal
22
Battery (−) input signal
Forward external
torque limit
Can be
Reverse external
allocated
torque limit
Dynamic brake answer
signal
tions.
trols, and not by electrical or mechanical means. If the application does not satisfy the safety requirements, add
an external circuit for safety reasons as required.
Function
With overtravel prevention: Stops servomotor when movable
part travels beyond the allowable range of motion.
Connects the deceleration limit switch for homing.
Connects the external signals that latch the current feedback
pulse counter.
Used for general-purpose input.
Monitored in the I/O monitor field of MECHATROLINK.
Control power supply input for sequence signals.
Allowable voltage fluctuation range: 11 to 25 V
Note: The 24 VDC power supply is not included.
Connecting pin for the absolute encoder backup battery.
Do not connect when the encoder cable with the battery case
is used.
The allocation of an input signal to a pin can be changed in
accordance with the function required.
Refer-
ence
Section
4.3.1
3.5.1
3.8.2
4.6.1