Starting Motor Dismounting and Remounting
Dismounting
1) Disconnect negative (–) battery lead at battery.
2) Disconnect magnetic switch lead wire (1) and battery cable (2) from starting motor terminals.
3) Remove starting motor mount bolt (3) and nut (4).
4) Remove starting motor (5).
Remounting
Reverse the dismounting procedure.
Tightening torque
Starting motor battery cable nut for 1.0 kW type (a): 9.0 N·m (0.9 kgf-m, 6.5 lb-ft)
Starting motor battery cable nut for 1.2 kW and 1.4 kW type (a): 10 N·m (1.0 kgf-m, 7.5 lb-ft)
Repair Instructions
Starting System:
1I-4
S3RH0A1906001
I3RH0A190001-01