TPCME
Transfer Captured Master Encoder Position
Type
Transfer
Syntax
<a_><!>TPCME
Units
n/a
Range
n/a
Default
n/a
Response
TPCME
*TPCME+0
See Also
INFNC, MEPOL, MESND, [ PME ], [ PCME ], [ PCMS ], PMECLR,
PMESET, TPME, TPCMS
Use the
command to display the current captured master encoder position. The master encoder is
TPCME
connected to the connector labeled "Master Encoder."
Syntax:
where
VARn=PCME
.
IF(PCME>2345Ø)
About Position Capture: The master encoder position can be captured only by the Master Trigger input
(input #5), and only when that input is defined as a "trigger interrupt" input with the
(see
command). When the "trigger interrupt" input is activated (active edge), the master encoder
INFNC
position is captured and the position is available through the use of the
display command.
Position Capture Status, Longevity of Captured Position: Use the
ascertain if a trigger interrupt input has been activated.
is an assignment/comparison operator for using the status information in a conditional expression
TRIG
(e.g., in an
statement). Once the captured master encoder position value is displayed with the
IF
command,
/
status bit #5 is cleared; but the position information remains available until it is
TTRIG
TRIG
overwritten by a subsequent position capture from the master trigger input.
Position Capture Accuracy: The master encoder position capture accuracy is ±1 encoder count.
Scaling and Position Offset: The
you issue a
(establish absolute position reference) command, any previously captured master
PMESET
encoder positions will be offset by the
TPCMS
Transfer Captured Master Cycle Position
Type
Transfer
Syntax
<a_><!>TPCMSc
Units
c = trigger input letter (A, B or M)
(Reported value represents master counts, scalable by SCLMAS)
Range
n/a
Default
n/a
Response
TPCMSA
*TPCMSA+0
See Also
ENCCNT, FOLMAS, INFNC, [ PCMS ], PSET, SCALE, SCLMAS, SFB,
TPCME, [ TRIG ], TRGLOT, TTRIG
The
command transfers the captured position of the master within its current master cycle.
TPCMS
(and
) is unique among position transfers, because its value rolls over to zero each time the
TPCMS
TPMAS
entire master cycle length (
FMCLEN
snap-shot of the position relative to the master cycle at the time of the capture.
The master must be assigned first (
For a complete discussion of master cycles, refer to the Following chapter in the Programmer's Guide.
is the variable number; or
n
PCME
TTRIG
value is always in master encoder counts; it is never scaled. If
TPCME
command value.
PMESET
) has been traveled. Thus, the captured
command) before this command will be useful.
FOLMAS
www.comoso.com
Product
GT6K
GV6K
can be used in an expression such as
INFNC5-H
operator and the
PCME
and
commands to
TTRIG
TRIG
displays the status as a binary report, and
Product
GT6K
GV6K
value is essentially a
TPCMS
Command Descriptions
Rev
6.0
6.0
command
TPCME
TPCME
Rev
6.0
6.0
307