[ DPTR ]
Data Pointer Location
Type
Data Storage; Assignment or Comparison
Syntax
see below
Units
n/a
Range
n/a
Default
n/a
Response
n/a
See Also
[ DAT ], DATA, [ DATP ], DATPTR, DATSIZ, TDPTR
The
command can be used to compare the current pointer location (the number of the data element to
DPTR
which the data pointer is pointing) against another value or numeric variable, or to assign the pointer location
number to a variable. The current data pointer location is referenced to the current active data program
specified in the first integer of the last
Syntax:
where "
VARn=DPTR
or
can be used in an expression such as
DPTR
Example:
DATSIZ4,200
; Create data program called DATP4 with 200 data elements
DATPTR4,20,2
; Set the data pointer to data element #20 in DATP4 and set the
; increment to 2 (DATP4 becomes the current active data program)
VAR1=DPTR
; Assign the number of the pointer location in DATP4 to numeric
; variable #1
VAR1
; Response is *VAR1=20. Indicates that the data pointer is
; pointing to data element #20.
DPWM
Drive PWM Frequency
Type
Drive Configuration
Syntax
<a_><!>DPWM <i>
power)
Units
kHz
Range
0, 8, 16, 20 or 40
Default
0 (use the drive's default frequency):
GV6K-U3, GV6K-U6, GV6K-U12, GV6K-H20, GV6K-H40: 8 KHz
GV6K-L3: 40 KHz
Response
DPWM8
See Also
NOTE: This command does not take effect until you cycle power to the drive, or issue a
command.
Use the
command to select the drive's PWM frequency. This value is the internal PWM frequency as
DPWM
seen at the motor windings; the motor ripple current is twice this frequency. In general, for a given drive
power level, the higher the switching frequency, the lower the motor ripple current heating and the lower
both the peak and continuous current ratings.
The table below lists the drive's continuous current and peak current ratings for different PWM
frequencies.
Drive
Input Voltage
GV6K-L3
120VAC, 1 phase
GV6K-U3*
240VAC, 1 phase
GV6K-U6*
240VAC, 1 phase
GV6K-U12*
240VAC, 1 phase
GV6K-H20
240VAC, 1 phase
GV6K-H20
240VAC, 3 phase
GV6K-H40
240VAC, 1 phase
GV6K-H40
240VAC, 3 phase
* Current Ratings are the same for 120VAC operation
Note: All currents are peak of the sine wave values
100
Gemini GV6K/GT6K Command Reference
or
command.
DATSIZ
DATPTR
" is the variable number,
n
IF(DPTR=1)
(does not take effect until RESET, DRESET or cycle
CONTINUOUS CURRENT
DPWM8 DPWM16 DPWM20 DPWM40
n/a
n/a
n/a
3.0A
n/a
n/a
6.0A
4.5A
3.6A
12.0A
9.0A
7.2A
16.0A
13.0A
11.0A
20.0A
13.0A
11.0A
23.1A
23.1A
22.0A
40.0A
26.0A
22.0A
www.comoso.com
RESET
PEAK CURRENT
DPWM8 DPWM16 DPWM20 DPWM40
3.0A
n/a
n/a
n/a
7.5A
n/a
n/a
15.0A
11.2A
n/a
20.0A
22.5A
n/a
50.0A
32.5A
n/a
50.0A
32.5A
n/a
100.0A
65.0A
n/a
100.0A
65.0A
Product
Rev
GT6K
6.0
GV6K
6.0
Product
Rev
GT6K
n/a
GV6K
6.0
(applicable only to
servo axes)
or
DRESET
n/a
7.5A
n/a
n/a
9.0A
n/a
18.0A
n/a
27.5A
n/a
27.5A
n/a
55.0A
n/a
55.0A
n/a