Fan Module Events (300 through 399)

Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
One cooling fan (out of six) failed or is rotating at insufficient angular velocity. The
remaining fans are operational. The amber LED illuminates at the rear of the fan
module associated with the failed fan.
Action:
Replace the indicated fan module.
Event Data:
The first byte of event data (byte 0) specifies the failed fan number.
Distribution:
Director
EWS
Event
Log
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Two cooling fans (out of six) failed or are rotating at insufficient angular velocity.
The remaining fans are operational. The amber LED illuminates at the rear of the
fan modules associated with the failed fans.
Action:
Replace the indicated fan modules.
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers.