Map 0100: Power Distribution Analysis; Map 0100: Event Codes - HP storageworks director 2/140 Service Manual

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

MAP 0100: Power Distribution Analysis

This MAP describes fault isolation for the director power distribution system,
including defective AC power cords, redundant power supplies, or the power
module assembly.
1
Was an event code 200, 201, 202, or 208 observed at the Director 2/140 Event
Log (HAFM appliance) or at the Embedded Web Server Event Log?
YES
2
Table 6
that describe fault isolation procedures.
Table 6: MAP 0100: Event Codes
Event Code
3
A redundant power supply is disconnected from facility power, not properly
installed, or has failed.
Verify the power supply is connected to facility power.
1. Ensure the AC power cord associated with the power supply (PS0 or PS1) is
2. Ensure the associated facility circuit breaker is on. If not, ask the customer to
3. Ensure the AC power cord is not damaged. If damaged, replace the cord.
Director 2/140 Service Manual
NO
Go to
step
10.
lists event codes, brief explanations of the codes, and the associated steps
200
Power supply AC voltage failure.
201
Power supply DC voltage failure.
202
Power supply thermal failure.
208
Power supply false shutdown.
connected to the rear of the director and a facility power receptacle. If not,
connect the cord as directed by the customer.
set the circuit breaker on.
Explanation
Diagnostics
Action
Go to
step 3
Go to
step 7
Go to
step 7
Go to
step 8
69