HP storageworks director 2/140 Service Manual page 55

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

If a link incident occurred, the affected port number is listed with one of the
following messages.
Did one of the listed messages display in the Link Incident Log?
YES
A link incident problem is indicated. Go to
event codes are found, go to
Analysis" on page 115. Exit MAP.
23
Obtain event codes from the director Event Log.
Note:
Record the date, time, and listed sequence, and determine if the codes are related to
the reported problem. Begin fault isolation with the most recent event code with the
highest severity level. Other codes may accompany this event code, or may indicate a
normal indication after a problem has been recovered.
1. At the Hardware View, choose Logs > Event Log. The Event Log displays,
2. Record the event code, date, time, and severity (Informational, Minor,
3. Record all event codes that may relate to the reported problem.
Director 2/140 Service Manual
Link interface incident-implicit incident.
Link interface incident-bit-error threshold exceeded.
Link failure-loss of signal or loss of synchronization.
Link failure-not-operational primitive sequence (NOS) received.
Link failure-primitive sequence timeout.
Link failure-invalid primitive sequence received for the current
link state.
NO
The director is operational. Exit MAP.
If multiple event codes are found, note all codes and associated severity levels.
as shown in
Figure
13.
Major, or Severe).
step 23
"MAP 0600: UPM Card Failure and Link Incident
to obtain event codes. If no
Diagnostics
55