Fan Module Events (300 through 399)

Table 55: Event Code 300
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
One cooling fan (out of six) failed or is rotating at insufficient angular velocity. The
remaining fans are operational. The amber LED illuminates at the rear of the power
supply assembly associated with the failed fan.
Action:
Replace the power supply assembly containing the indicated fan module.
Event Data:
The first byte of event data (byte 0) specifies the failed fan number (0 through 5
inclusive).
Distribution:
Switch
EWS
Event
Log
Table 56: Event Code 301
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Two cooling fans (out of six) failed or are rotating at insufficient angular velocity.
The remaining fans are operational. The amber LED illuminates at the rear of the
power supply assembly (or assemblies) associated with the failed fans.
Action:
Replace the power supply assembly (or assemblies) containing the indicated fan
modules.
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers (0 through 5
inclusive).
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/24 Service Manual
HAFM Server
System
Event
Error
Log
LED
HAFM Server
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
247

Advertisement

Table of Contents
loading

Table of Contents