Did the HAFM appliance reconfigure as a client and did the Ethernet connection
recover?
NO
Contact the next level of support. Exit MAP.
21
The IP address defining the director to the HAFM application is incorrect or
unknown and must be verified. A maintenance terminal (PC) and asynchronous
RS-232 null modem cable are required to verify the director's IP address. The
tools are provided with the director or by service personnel. To verify the IP
address:
1. Remove the protective cap from the 9-pin maintenance port at the rear of the
2. Connect the other cable end to a 9-pin communication port (COM1 or
3. Power on the maintenance terminal. After the PC powers on, the Windows
4. Choose Start > Programs > Accessories > HyperTerminal. The
Note:
serial communication software.
5. Type 140 in the Name field and click OK. The Connect To dialog box
6. Ensure the Connect using field displays COM1 or COM2 (depending on the
Director 2/140 Service Manual
YES
The director-to-HAFM appliance connection is restored and the
second HAFM appliance is operational as a client. Exit MAP.
director (a Phillips-tip screwdriver may be required). Connect one end of the
RS-232 null modem cable to the port.
COM2) at the rear of the maintenance terminal PC.
desktop displays.
Connection Description dialog box displays.
The following steps describe inspecting the IP address using
displays.
serial communication port connection to the director), and click OK. The
COMn Properties dialog box displays (where n is 1 or 2).
Diagnostics
HyperTerminal
101