Map 0700: Byte 4, Segmentation Reasons - HP storageworks director 2/140 Service Manual

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Table 18: MAP 0700: Byte 4, Segmentation Reasons
13
As indicated by an event code 072, a director E_Port is connected to an
unsupported switch or fabric element.
Advise the customer of the problem and disconnect the interswitch link to the
unsupported switch. Exit MAP.
14
A director E_Port segmented because the error detect time out value (E_D_TOV)
or resource allocation time-out value (R_A_TOV) is incompatible with the
attached fabric element.
1. Contact HP customer support or engineering personnel to determine the
2. Notify the customer that both directors will set offline. Ensure the system
3. Set both directors offline
4. At the Hardware View for the first director reporting the problem, choose
5. Type the recommended E_D_TOV and R_A_TOV values, then click
6. Repeat
Director 2/140 Service Manual
Byte 4
Segmentation Reason
01
Incompatible operating parameters.
02
Duplicate domain IDs.
03
Incompatible zoning configurations.
04
Build fabric protocol error.
05
No principal switch.
06
No response from attached switch.
07
ELP retransmission failure timeout.
recommended E_D_TOV and R_A_TOV values for both directors.
administrator quiesces Fibre Channel frame traffic through the directors and
sets attached devices offline.
Configure > Operating Parameters > Fabric Parameters. The Configure
Fabric Parameters dialog box displays, as shown in
Activate.
step 4
and
step 5
the segmented E_Port (second director). Use the same E_D_TOV and
R_A_TOV values.
("Set Offline
State" on page 201).
at the Hardware View for the director attached to
Diagnostics
Action
Go to
step 14
Go to
step 15
Go to
step 16
Go to
step 17
Go to
step 19
Go to
step 20
Go to
step 21
Figure
29.