HP storageworks director 2/140 Service Manual page 168

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Repair Information
Table 22: Port Operational States (Continued)
Invalid
Attachment
Link Incident
Link Reset
No Light
Not
Operational
Port Failure
168
Port
Green
State
LED
On
Off
Off
Off
Off
Off
Amber
Alert
LED
Symbol
Off
Yellow
Triangle
Off
Yellow
Triangle
Off
Yellow
Triangle
Off
None
Off
Yellow
Triangle
On
Red and
Yellow
Blinking
Diamond
Description
The director port has an invalid
attachment state if:
(1) a loopback plug is
connected to the port with no
diagnostic test running, or
(2) the port is cabled to another
port on the same director, or
(3) the port connection conflicts
with the configured port type.
A link incident occurred on the
port. The alert symbol displays
at the Port Card View, Port List
View, and Hardware View.
The director and attached
device are performing a link
reset operation to recover the
link connection. This is a
transient state that should not
persist.
No signal (light) is received by
the director port. This is a
normal condition when there is
no cable attached to the port or
when the attached device is
powered off.
The director port is receiving the
not operational sequence
(NOS) from an attached device.
The director port failed and
requires service.
Director 2/140 Service Manual

Advertisement

Table of Contents
loading

Table of Contents