HP storageworks director 2/140 Service Manual page 38

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Diagnostics
Table 5: Event Codes and Corresponding Maintenance Action (Continued)
38
Event
Code
Explanation
142
Low BB_Credit detected on an
ISL.
143
Low BB_Credit relieved on an
ISL.
150
Zone merge failure.
151
Fabric configuration failure.
200
Power supply AC voltage
failure.
201
Power supply DC voltage
failure.
202
Power supply thermal failure.
203
Power supply AC voltage
recovery.
204
Power supply DC voltage
recovery.
206
Power supply removed.
207
Power supply installed.
208
Power supply false shutdown.
300
Cooling fan propeller failed.
301
Cooling fan propeller failed.
302
Cooling fan propeller failed.
Action
Go to
MAP 0700: Fabric, ISL,
and Segmented Port Problem
Determination.
No action required.
Go to
MAP 0700: Fabric, ISL,
and Segmented Port Problem
Determination.
If this event persists, perform
data collection procedure
("Collecting Maintenance
on page 192) and return backup
CD to HP support personnel.
Go to
MAP 0100: Power
Distribution
Analysis.
Go to
MAP 0100: Power
Distribution
Analysis.
Go to
MAP 0100: Power
Distribution
Analysis.
No action required.
No action required.
Replace FRU.
No action required.
Go to
MAP 0100: Power
Distribution
Analysis.
Go to
MAP 0500: FRU Failure
Analysis
Go to
MAP 0500: FRU Failure
Analysis.
Go to
MAP 0500: FRU Failure
Analysis.
Director 2/140 Service Manual
Data"

Advertisement

Table of Contents
loading

Table of Contents