Message:
CTP firmware download initiated.
Severity:
Informational.
Explanation:
The HAFM appliance initiated download of a new firmware version to the director.
Action:
No action required.
Event Data:
No supplementary data included with this event.
Distribution:
Director
EWS
Event
Log
Message:
Multiple ECC single-bit errors occurred.
Severity:
Minor.
Explanation:
When the SDRAM controller detects an error checking and correction (ECC) error,
an interrupt occurs. If an interrupt occurs a certain number of times weekly, a 426
event code is recorded. The number of interrupts is indicated by the event data.
Action:
No action required. SDRAM is probably malfunctioning intermittently.
Event Data:
Byte 0 of the event data (equal to 5, 10, 15, or 20) is recorded. The number of
interrupts equals two to the power of the event data. Event data equal to 10
indicates 1,024 ECC error interrupts.
Distribution:
Director
EWS
Event
Log