HP storageworks director 2/140 Service Manual page 329

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Distribution:
Director
EWS
Event
Log
Message:
Director is isolated.
Severity:
Informational.
Explanation:
The director is isolated from other fabric elements (directors or switches). This event
code is accompanied by one or more 070 event codes. Refer to the event data for
the segmentation reason.
Action:
Action depends on the segmentation reason specified in the event data.
Event Data:
The first byte of event data (byte 0) specifies the E_Port number. The fifth byte (byte
4) specifies the segmentation reason as follows:
1 = Incompatible operating parameters. Ether the resource allocation time out value
(R_A_TOV) or error detect time out value (E_D_TOV) is inconsistent between the
Director 2/140 and another fabric element (director or switch). Modify the
R_A_TOV and E_D_TOV to make the values consistent for all fabric directors and
switches.
2 = Duplicate domain ID. The Director 2/140 has the same preferred domain ID as
another fabric element (director or switch). Modify the director's Domain ID to
make it unique.
3 = Incompatible zoning configurations. The same name is applied to a zone for
the Director 2/140 and another fabric element (director or switch), but the zones
contain different zone members. Modify the zone name to make it unique, or
ensure zones with the same name contain identical zone members.
Director 2/140 Service Manual
Event Code: 070 (continued)
HAFM appliance
System
Event
Error
Log
LED
Event Code: 071
E-Mail
Call
Home
Event Code Tables
Host
Sense
Link
Info
Incident
329

Advertisement

Table of Contents
loading

Table of Contents