Did optical transceiver replacement solve the problem?
NO
7
A UPM card failed, and the card must be removed and replaced
Card" on page 231).
Did UPM card replacement solve the problem?
NO
Contact the next level of support. Exit MAP.
8
Is fault isolation being performed at the HAFM appliance?
YES
Director 2/140 Service Manual
Perform an external loopback test for the port as part of FRU removal and
replacement.
YES
The director is operational. Exit MAP.
This procedure is concurrent and can be performed while director power is on.
Verify location of the failed port. For an OSI environment,
Figure 28
show UPM card numbers (0 through15) and port numbers (0-127
and 132-143). For a FICON environment,
UPM card numbers (0 through 15), port numbers (0-127 and 132-143), and
bolded logical port addresses (hexadecimal 04 through 8F).
Notify the customer that all ports on the defective card are to be blocked.
Ensure the customer's system administrator quiesces Fibre Channel frame
traffic through any operational ports on the card and sets attached devices
offline.
Perform an external loopback test for all ports on the replacement card as part
of FRU removal and replacement.
Perform the data collection procedure as part of FRU removal and
replacement.
YES
The director is operational. Exit MAP.
NO
Fault isolation is being performed at the Embedded Web Server
interface. Go to
Figure 27
step
42.
Diagnostics
("RRP: UPM
Figure 27
and
and
Figure 28
show
119