System Events (000 Through 199) - HP storageworks director 2/140 Service Manual

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

System Events (000 through 199)

Message:
System power-down.
Severity:
Informational.
Explanation
The director was powered off or disconnected from the facility AC power source.
:
The event code is distributed the next time the director powers on, but the date and
time of the code reflect the power-off time.
Action:
No action required.
Event Data:
No supplementary data included with the event.
Distribution:
Director
EWS
Event
Log
Message:
Login Server unable to synchronize databases.
Severity:
Minor.
Explanation:
Following a CTP card reset or replacement, the Login Server attempted to acquire
an up-to-date copy of its databases from the other CTP card, but failed. All Fabric
Services databases are initialized to an empty state, resulting in an implicit Fabric
logout of all attached devices.
Action:
Perform the data collection procedure and return the backup CD to HP support
personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
EWS
Event
Log