Map 0500: Fru Failure Analysis - HP storageworks director 2/140 Service Manual

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

MAP 0500: FRU Failure Analysis

This MAP describes fault isolation for the CTP card, SBAR assembly, and fan
module. Failure indicators include:
1
Was an event code 300, 301, 302, 303, 304, 305, 414, 420, 426, 433, 440, 604,
605, 607, 805, 806, 807, 810, 811, 812, or 850 observed at the director Event Log
(HAFM appliance) or at the Embedded Web Server Event Log?
YES
2
Table 11
that describe fault isolation procedures.
Table 11: MAP 0500: Event Codes
Event Code
Director 2/140 Service Manual
The amber LED on the FRU illuminates.
The amber emulated LED on a fan graphic at the Hardware View
illuminates.
A blinking red and yellow diamond (failed FRU indicator) displays over a
FRU graphic; or a grey square (status unknown indicator) or yellow triangle
(attention indicator) displays at the alert panel of the HAFM main window or
Hardware View.
An event code recorded at the director Event Log or the Embedded Web
Server Event Log.
A Failed message associated with a FRU at the Embedded Web Server
interface.
NO
Go to
step
3.
lists event codes, brief explanations of the codes, and associated steps
300
Cooling fan propeller failed.
301
Cooling fan propeller failed.
302
Cooling fan propeller failed.
303
Cooling fan propeller failed.
304
Cooling fan propeller failed.
305
Cooling fan propeller failed.
414
Backup CTP card failed.
Explanation
Diagnostics
Action
Go to
step 5
Go to
step 5
Go to
step 5
Go to
step 5
Go to
step 5
Go to
step 5
Go to
step 7
107