FRU Removal and Replacement
1
Power supply
1
Figure 77: Redundant power supply removal and replacement

Replacing the Power Supply

To replace a redundant power supply:
1. Remove the replacement power supply from its protective antistatic bag.
2. Inspect the rear of the power supply for bent or broken connector pins that
3. Insert the power supply into the chassis guide of the AC module, then push
4. Disconnect the ESD wrist strap from the director chassis and your wrist.
5. Inspect the power supply to ensure the green PWR OK LED is illuminated
242
2
may have been damaged during shipping. If any pins are damaged, obtain a
new power supply.
the power supply toward the backplane to engage the connector pins.
and all amber LEDs are extinguished. If a problem is indicated, go to
0000: Start
MAP" on page 45 to isolate the problem.