Diagnostics
9
Does a blinking red and yellow diamond (failed FRU indicator) display over a
UPM card graphic at the Hardware View or display adjacent to a Fibre Channel
port graphic at the Port Card View?
NO
10
Did a Fibre Channel port or UPM card (all ports) fail a loopback test?
NO
11
Does a yellow triangle (attention indicator) display over a UPM card graphic at
the Hardware View or display adjacent to a port graphic at the Port Card View?
YES
12
Inspect the port state and LED status for all ports with an attention indicator.
1. At the Port Card View, double-click the port graphic with the attention
2. Inspect the Operational State field at the Port Properties dialog box, and the
3.
120
YES
A port or UPM card failure is indicated. Go to
YES
Go to
step
14.
NO
Go to
step
13.
indicator. The Port Properties dialog box displays.
emulated green and amber LEDs adjacent to the port at the Port Card View.
Table 13
lists LED and port operational state combinations and associated
MAP 0600 (or other) steps that describe fault isolation procedures.
step
6.