Event Code Tables
Message:
SBAR assembly anomaly detected.
Severity:
Informational.
Explanation:
Director operational firmware detected a deviation in the normal operating mode
or operating status of the indicated SBAR assembly.
Action:
No action required. An event code 604 is generated if the SBAR assembly fails.
Event Data:
Byte 0 = SBAR slot position (00 or 01).
Byte 1 = anomaly reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = high-availability error callout #1.
Bytes 10 and 11 = high-availability error callout #2.
Byte 12 = detecting port.
Byte 13 = connected port.
Byte 14 = participating SBAR assembly.
Bytes 16 and 17 = high-availability error callout #3.
Bytes 18 and 19 = high-availability error callout #4.
Distribution:
Director
EWS
Event
Log
380
Event Code: 602
HAFM appliance
System
Event
Error
Log
LED
E-Mail