Did the domain ID change solve the problem and did both directors join through
the ISL to form a fabric?
NO
Contact the next level of support. Exit MAP.
16
A director E_Port segmented because two directors had incompatible zoning
configurations. An identical zone name is recognized in the active zone set for
both directors, but the zones contain different members.
1. Work with the system administrator to determine the desired zone name
2. Close the Element Manager (Hardware View). The HAFM main window
3. At the HAFM main window physical map, right-click the blue background
4. Choose Zoning. The Zoning dialog box displays with the Zone Library page
Director 2/140 Service Manual
YES
The directors, associated ISL, and multi-switch fabric are operational.
Exit MAP.
change for one of the affected directors. Zone names must conform to the
following rules:
The name must be 64 characters or fewer in length.
The first character must be a letter (a through z), upper or lower case.
Other characters are alphanumeric (a through z or 0 through 9), dollar sign
($), hyphen (-), caret (^), or underscore (_).
displays.
representing the fabric containing the switch reporting the problem. A pop-up
menu displays.
open, as shown in
Figure
37.
Diagnostics
145