9. At the Hardware View, double-click the graphic representing the
10. Restore communication to the replacement UPM card and set the card online
11. Perform the data collection procedure
12. Perform one of the following to clear the system error (ERR) LED:
13. If necessary, close and lock the equipment cabinet door.
Director 2/140 Service Manual
— 501—Port card has been recognized.
If an event code 501 does not display in the log, go to
MAP" on page 45 to isolate the problem.
replacement card to open the Port Card View. At the Port Card View:
a. Ensure no alert symbols display that indicate a failure (yellow triangle or
red diamond).
b. Verify that UPM card information (FRU name, position, and state) is
correct.
If a problem is indicated, go to
isolate the problem.
as directed by the customer
customer the UPM card is available for use.
page 192).
— If at the HAFM application, open the Hardware View and:
a. Right-click the front panel bezel graphic (away from a FRU) to open
a menu.
b. Click Clear System Error Light.
— If at an EWS interface:
a. Click the Switch tab at the Operations panel. The Operations panel
displays with the Switch page open.
b. Click the Sys Err Light tab. The Switch page displays with the Sys
Err Light tab selected. A System Error Light is ON
message displays on the page.
c. Click Clear Light.
"MAP 0000: Start
("Unblock a UPM
Card" on page 204). Inform the
("Collecting Maintenance
FRU Removal and Replacement
"MAP 0000: Start
MAP" on page 45 to
Data" on
235