HP storageworks director 2/140 Service Manual page 343

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Message:
Power supply thermal failure.
Severity:
Major.
Explanation:
The thermal sensor associated with a power supply indicates an overheat condition
that shut down the power supply. The second power supply assumes the full
operating load for the director.
Action:
Replace the failed power supply. Perform the data collection procedure and return
the backup CD and failed power supply to HP support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
EWS
Event
Log
Message:
Power supply AC voltage recovery.
Severity:
Informational.
Explanation:
AC voltage recovered for the power supply. Both power supplies adjust to share
operating load for the director.
Action:
No action required.
Event Data:
No supplementary data included with the event.
Distribution:
Director
EWS
Event
Log
Director 2/140 Service Manual
Event Code: 202
HAFM appliance
System
Event
Error
Log
LED
Event Code: 203
HAFM appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Code Tables
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
343

Advertisement

Table of Contents
loading

Table of Contents