HP storageworks director 2/140 Service Manual page 123

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

16
A director port is unblocked and receiving the offline sequence (OLS) or not
operational sequence (NOS) from an attached device.
Inform the customer that the attached device failed or is set offline. Exit MAP.
17
Beaconing is enabled for the port.
1. Consult the customer and next level of support to determine the reason port
2. Disable port beaconing.
Was port beaconing enabled because port failure or degradation was suspected?
YES
Go to
18
The eight-byte (16-digit) worldwide name (WWN) entered to configure port
binding is not valid or a nickname was used that is not configured for the attached
device in the Element Manager.
At the Hardware View, choose Node List. Note the Port WWN column. This is
the WWN assigned to the port or Fibre Channel interface installed on the attached
device.
The bound WWN must be entered in the form of a raw WWN format
(XX:XX:XX:XX:XX:XX:XX:XX) or must be a valid nickname. Ensure a valid
WWN or nickname is entered.
Director 2/140 Service Manual
beaconing is enabled.
a. At the Port Card View, right-click the port graphic. A menu displays.
b. Click Enable Beaconing. The check mark disappears from the box
adjacent to the option, and port beaconing is disabled.
NO
The director is operational. Exit MAP.
step
1.
If a nickname is not assigned to the WWN, the WWN is prefixed by the
device manufacturer name.
If a nickname is assigned to the WWN, the nickname displays in place of the
WWN.
Diagnostics
123