Table 5: Event Codes and Corresponding Maintenance Action (Continued)
Director 2/140 Service Manual
Event
Code
Explanation
582
Bit error threshold exceeded.
583
Loss of signal or loss of
synchronization.
584
Not operational primitive
sequence received.
585
Primitive sequence timeout.
586
Invalid primitive sequence
received for current link state.
600
SBAR assembly hot-insertion
initiated.
601
SBAR assembly recognized.
602
SBAR assembly anomaly
detected.
603
SBAR assembly hot-removal
completed.
604
SBAR assembly failure.
605
SBAR assembly revision not
supported.
607
Director contains no
operational SBAR assemblies.
608
User initiated SBAR switch-over.
800
High temperature warning
(UPM card thermal sensor).
Action
Go to
MAP 0600: UPM Card
Failure and Link Incident
Analysis.
Go to
MAP 0600: UPM Card
Failure and Link Incident
Analysis.
Go to
MAP 0600: UPM Card
Failure and Link Incident
Analysis.
Go to
MAP 0600: UPM Card
Failure and Link Incident
Analysis.
Go to
MAP 0600: UPM Card
Failure and Link Incident
Analysis.
No action required.
No action required.
No action required.
No action required.
Go to
MAP 0500: FRU Failure
Analysis.
Go to
MAP 0500: FRU Failure
Analysis.
Go to
MAP 0500: FRU Failure
Analysis.
No action required.
Go to
MAP 0600: UPM Card
Failure and Link Incident
Analysis.
Diagnostics
43