Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Three cooling fans (out of six) failed or are rotating at insufficient angular velocity.
The remaining fans are operational. The amber LED illuminates at the rear of the
fan modules associated with the failed fans.
Action:
Replace the indicated fan modules.
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution:
Director
EWS
Event
Log
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Four cooling fans (out of six) failed or are rotating at insufficient angular velocity.
The remaining fans are operational. The amber LED illuminates at the rear of both
fan modules.
Action:
Replace both fan modules
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution:
Director
EWS
Event
Log
Director 2/140 Service Manual
Event Code: 302
HAFM appliance
System
Event
Error
Log
LED