Table 13: MAP 0600: Port Operational and LED States
Operational State
Offline
Not Operational
Testing
Testing
Beaconing
Invalid Attachment
Link Reset
Link Incident
Segmented E_Port
13
A link incident may have occurred, but the LIN alerts option is not enabled for the
port and the attention indicator does not display.
At the Hardware View, choose Logs > Link Incident Log. The Link Incident
Log displays. If a link incident occurred, the affected port number is listed with
one of the following messages.
Director 2/140 Service Manual
Link interface incident-implicit incident.
Link interface incident-bit-error threshold exceeded.
Link failure-loss of signal or loss of synchronization.
Link failure-not-operational primitive sequence (NOS) received.
Link failure-primitive sequence timeout.
Link failure-invalid primitive sequence received for the current
link state.
Green LED
Amber LED
Off
Off
Off
Off
Off
Blinking
On
Blinking
Off or On
Blinking
On
Off
Off
Off
Off
Off
On
Off
Diagnostics
Action
Go to
step 16
Go to
step 16
Internal loopback test in
process.
Exit MAP.
External loopback test
in process.
Exit MAP.
Go to
step 17
Go to
step 19
Go to
step 32
Go to
step 33
Go to
MAP 0700:
Fabric, ISL, and
Segmented Port
Problem
Determination.