Diagnostics
6
Inspect the faceplates of both CTP cards at the front of the director.
Is the amber LED at the top of a CTP card illuminated but not blinking
(beaconing)?
YES
7
A CTP card failed and must be removed and replaced
Card" on page 226).
Note:
operational and director power is on. The director IP address, configuration data, and
other operating parameters will be lost.
Did CTP card replacement solve the problem?
NO
Contact the next level of support. Exit MAP.
8
Inspect both SBAR assemblies at the rear of the director. SBAR assembly LEDs
can be inspected through the hexagonal cooling vents of the RFI shield.
Is the amber LED on an SBAR assembly illuminated but not blinking
(beaconing)?
YES
110
NO
Go to
step
8.
This procedure is concurrent and can be performed while director power is on.
Perform the data collection procedure as part of FRU removal and
replacement.
Do not remove and replace a CTP card if the backup CTP card is not fully
YES
The director is operational. Exit MAP.
NO
The director is operational. Exit MAP.
("RRP: Redundant CTP