HP storageworks director 2/140 Service Manual page 117

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Table 12: MAP 0600: Event Codes (Continued)
Event Code
4
Is fault isolation being performed at the director?
YES
5
Inspect the faceplates of UPM cards at the front of the director. Each card has an
amber LED (at the top of the card) that illuminates if the card fails or if any Fibre
Channel port fails.
Each card also has a bank of amber and green LEDs above the ports. Each LED
pair is associated with a corresponding port (for example, the top LED pair is
associated with the top port). The amber LED illuminates and the green LED
extinguishes if the port fails.
Are an amber port LED and the amber LED at the top of the UPM card
illuminated but not blinking (beaconing)?
YES
6
A Fibre Channel port failed, and the SFP optical transceiver must be removed and
replaced
Director 2/140 Service Manual
586
Invalid primitive sequence received for current
link state.
800
High temperature warning (UPM card thermal
sensor).
801
Critically hot temperature warning (UPM card
thermal sensor).
802
UPM card shutdown due to thermal violation.
NO
Fault isolation is being performed at the HAFM appliance or
Embedded Web Server interface. Go to
NO
The director is operational, however a link incident or other problem
may have occurred. Perform fault isolation at the HAFM appliance.
Go to
step
8.
("RRP: SFP Optical
This procedure is concurrent and can be performed while director power is on.
Explanation
Transceiver" on page 236).
Diagnostics
Action
Go to
Go to
Go to
Go to
step
8.
step 24
step 7
step 7
step 7
117

Advertisement

Table of Contents
loading

Table of Contents