Replacing The Upm Card - HP storageworks director 2/140 Service Manual

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

FRU Removal and Replacement

Replacing the UPM Card

To replace a UPM card:
1. Remove the replacement card from its protective antistatic bag.
2. Hold the card by its stiffener and insert it in the chassis card track, as shown in
3. Secure the UPM card:
4. Perform an external loopback test for all ports on the replacement UPM card
5. Reconnect a fiber optic jumper cable to each port on the card. Inspect the label
6. Disconnect the ESD wrist strap from the director chassis and your wrist.
7. Inspect the UPM card to ensure all amber LEDs are extinguished. If any
8. At the Hardware View, choose Logs > Event Log. The Event Log displays.
234
Figure
74. The label identifying the card should be at the top. Verify the card
is aligned in the card tracks, then slide it forward until it makes contact with
the backplane.
a. Insert the torque tool into the cam Allen screw (uncolored). Turn the
torque tool clockwise until you feel it release and hear a clicking sound.
As the screw turns clockwise, the card cams into the backplane connector.
b. Insert the torque tool into the locking Allen screw (yellow). Turn the
torque tool clockwise until you feel it release and hear a clicking sound.
As the screw turns clockwise, the card locks into place.
c. Verify the card stiffener is flush with the front of the card cage and even
with other director logic cards.
("External Loopback
Start
MAP" on page 45 to isolate the problem.
on the jumper cable to ensure the correct connection. Repeat this step for all
four ports.
a. Remove the protective cap from the cable connector and the protective
plug from the port's optical transceiver. Store the cap and plug in a suitable
location for safekeeping.
b. Clean the cable and port connectors
page 194).
c. Insert the keyed LC cable connector into the port's optical transceiver.
amber LEDs are illuminated, go to
isolate the problem.
Ensure the following event codes display in the log:
— 500—Port card hot-insertion initiated.
Test" on page 187). If the test fails, go to
("Clean Fiber Optic
"MAP 0000: Start
"MAP 0000:
Components" on
MAP" on page 45 to
Director 2/140 Service Manual