7. Modify the incompatible zone name as directed by the customer:
Did the zone name change solve the problem and did both directors join through
the ISL to form a fabric?
NO
Contact the next level of support. Exit MAP.
17
A director E_Port segmented because a build fabric protocol error was detected.
1. Disconnect the fiber optic jumper cable from the segmented E_Port.
2. Reconnect the cable to the same port.
Did disconnecting and reconnecting the cable solve the problem and did both
directors join through the ISL to form a fabric?
NO
18
Initial program load (IPL) the director
page 197).
Director 2/140 Service Manual
a. At the Zoning dialog box, click the Zone Library tab. The dialog box
returns to the Zone Library page, as shown in
b. Right-click the zone name to be changed from the Zones field. A pop-up
menu displays.
c. Choose the Rename option from the menu. The selected zone name
remains highlighted in blue.
d. Enter the new zone name (specified by the customer).
e. Click OK to activate the change and close the Zoning dialog box.
YES
The directors, associated ISL, and multi-switch fabric are operational.
Exit MAP.
YES
The directors, associated ISL, and multi-switch fabric are operational.
Exit MAP.
Figure
("IML, IPL, or Reset the
Diagnostics
37.
Director" on
147