Event Code Tables
Event Data:
Bytes 0-12 are the sequence number from the system VPD.
Bytes 13-31 are the OEM serial number obtained from the system VPD.
Distribution:
Director
EWS
Event
Log
Message:
Switch speed incompatibility detected.
Severity:
Informational
Explanation:
The event occurs when the configured switch speed saved in NVRAM conflicts with
the speed capability of the switch. This event may occur when backup CTP
hardware running an early version of software (below 1.3) is improperly
synchronized with a CTP operating at greater than 1Gb/s.
Action:
None. Switch speed configuration and port speed configuration data will be set to
a level that is compatible with the CTP and the CTP will automatically be IPLed.
Event Data:
None
Distribution:
Director
EWS
Event
Log
Message:
Backup CTP incompatible with configured systems settings.
Severity:
Informational
Explanation:
This event occurs when the backup CTP is failed as a result of being incompatible
with current system settings. Normally this event will be generated following a
hot-plug or power-on reset. (This event usually occurs when a CTP is installed into a
system operating at a switch speed not supported by the CTP). This event should be
followed by a 414 event.
Action:
Replace the backup CTP with a version of hardware capable of supporting the
user-configured settings or adjust the user settings to be compatible with the backup
CTP and reseat the backup CTP.
364
HAFM appliance
System
Event
Error
Log
LED
Event Code: 451
HAFM appliance
System
Event
Error
Log
LED
Event Code: 452