Message:
SBAR assembly revision not supported.
Severity:
Minor.
Explanation:
The indicated SBAR assembly is not recognized and displays as uninstalled to the
director firmware.
Action:
Ensure the director model supports the operating firmware version. If the firmware
version is supported, replace the SBAR assembly with a functional assembly.
Perform the data collection procedure and return the backup CD and faulty
assembly to HP support personnel.
Event Data:
Byte 0 = SBAR slot position (00 or 01).
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = detected module identifier.
Distribution:
Director
EWS
Event
Log
Message:
Director contains no operational SBAR assemblies.
Severity:
Severe.
Explanation:
The director firmware does not recognize an installed SBAR assembly.
Action:
Install at least one functional SBAR assembly and power-on reset (POR) the
director.
Event Data:
Bytes 4 through 7 = elapsed millisecond tick count.