HP storageworks director 2/140 Service Manual page 112

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Diagnostics
13
Is a blinking red and yellow diamond (failed FRU indicator) overlaying an SBAR
assembly graphic at the Hardware View?
NO
14
At the Hardware View, is a grey square displayed at the alert panel, a No Link
status displays at the Director 2/140 Status table, and graphical FRUs are
uninstalled?
YES
The grey square indicates the HAFM appliance cannot communicate with the
director because:
Continue to the next step.
15
At the director, inspect the amber LED at the top of each CTP card.
Is the amber LED illuminated on both CTP cards?
NO
Analysis for an Ethernet link or AC power distribution failure is not described in
this MAP. Go to
this step, contact the next level of support. Exit MAP.
112
YES
An SBAR assembly failure is indicated. Go to
NO
A green circle displays at the alert panel and the director is
operational. Exit MAP.
The director-to-HAFM appliance Ethernet link failed.
AC power distribution in the director failed, or AC power was disconnected.
Both of the director's CTP cards failed.
YES
Failure of both CTP cards is indicated. Go to
"MAP 0000: Start
MAP" on page 45. If this is the second time at
Director 2/140 Service Manual
step
9.
step
7.

Advertisement

Table of Contents
loading

Table of Contents