Thermal Events (800 through 899)
Message:
High temperature warning (UPM card thermal sensor).
Severity:
Major.
Explanation:
The thermal sensor associated with a UPM card indicates the warm temperature
threshold was reached or exceeded.
Action:
Replace the indicated UPM card with a functional UPM card of the same type.
Perform the data collection procedure and return the backup CD and faulty card to
HP support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
EWS
Event
Log
Message:
Critically hot temperature warning (UPM card thermal sensor).
Severity:
Major.
Explanation:
The thermal sensor associated with a UPM card indicates the hot temperature
threshold was reached or exceeded.
Action:
Replace the indicated UPM card with a functional UPM card of the same type.
Perform the data collection procedure and return the backup CD and faulty card to
HP support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
EWS
Event
Log
Director 2/140 Service Manual
Event Code: 800
HAFM appliance
System
Event
Error
Log
LED
Event Code: 801
HAFM appliance
System
Event
Error
Log
LED
E-Mail
Call