HP storageworks director 2/140 Service Manual page 122

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Diagnostics
Did one of the listed messages display in the Link Incident Log?
YES
Go to
14
A Fibre Channel port or UPM card (all ports) failed an internal or external
loopback test.
1. Reset each port that failed the loopback test.
2. Perform an external loopback test for all ports that were reset.
Did resetting ports solve the problem?
NO
15
An electronic circuit breaker on the UPM card may have tripped. To reset the
circuit breaker, partially remove and reseat the UPM card for which external
loopback tests failed
1. Unseat and disconnect the UPM card from the backplane. Unseat the card
2. Reseat the UPM card in the backplane.
3. Perform an external loopback test on the UPM card.
Did reseating the UPM card solve the problem?
NO
Go to
122
NO
The director is operational. Exit MAP.
step
33.
a. At the Hardware View, right-click the port. A menu displays.
b. Choose Reset Port. A Reset Port n message box displays, where n
is the port number.
c. Click OK. The port resets.
YES
The director is operational. Exit MAP.
("RRP: UPM
only, do not remove it from the director chassis.
YES
The director is operational. Exit MAP.
step
7.
Card" on page 231).
Director 2/140 Service Manual

Advertisement

Table of Contents
loading

Table of Contents