Message:
Congestion detected on an ISL.
Severity:
Informational.
Explanation:
Open Trunking firmware detected an ISL with Fibre Channel traffic that previously
exceeded the configured congestion threshold.
Action:
No action is required for an isolated event. If this event persists, relieve the
congestion by adding parallel ISLs, increasing the ISL link speed, or moving device
connections to a less-congested region of the fabric.
Event Data:
Byte 0 = Port number reporting congestion relieved.
Distribution:
Director
EWS
Event
Log
Message:
Congestion relieved on an ISL.
Severity:
Informational.
Explanation:
Open Trunking firmware detected an ISL with Fibre Channel traffic that previously
exceeded the configured congestion threshold. The congestion is now relieved.
Action:
No action required.
Event Data:
Byte 0 = Port number reporting congestion relieved.
Distribution:
Director
EWS
Event
Log
Director 2/140 Service Manual
Event Code: 140
HAFM appliance
System
Event
Error
Log
LED
Event Code: 141
HAFM appliance
System
Event
Error
Log
LED