Table 16: MAP 0700: Event Codes (Continued)
Event Code
3
Is fault isolation being performed at the HAFM appliance?
YES
4
Does a yellow triangle (attention indicator) display over a UPM card graphic at
the Hardware View?
YES
5
Inspect the port state and LED status for all ports with an attention indicator.
1. At the Hardware View, double-click the port graphic with the attention
2. Inspect the Operational State field at the Port Properties dialog box.
Director 2/140 Service Manual
052
HAFM appliance internal error.
060
Fabric controller unable to synchronize
databases.
061
Fabric controller database invalid.
062
Maximum interswitch hop count exceeded.
063
Received link state record too large.
070
E_Port is segmented.
071
Director is isolated.
072
E_Port connected to unsupported switch.
140
Congestion detected on an ISL.
142
Low BB_Credit detected on an ISL.
150
Zone merge failure.
NO
Fault isolation is being performed through the Embedded Web Server
interface. Go to
NO
The problem is transient and the director-to-fabric element
connection is operational. Exit MAP.
indicator. The Port Properties dialog box displays.
Explanation
step
26.
Diagnostics
Action
Go to
step 8
Go to
step 9
Go to
step 9
Go to
step 10
Go to
step 11
Go to
step 12
Go to
step 12
Go to
step 13
Go to
step 21
Go to
step 26
Go to
step 27
139