Clear Link Incident Alert(S) - HP storageworks director 2/140 Service Manual

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Did updating the switch membership lists solve the problem?
NO
Contact the next level of support. Exit MAP.
31
A port connection is not allowed because of a Computer Network Technologies
(CNT) wide area network (WAN) extension mode mismatch. Based on
switch-to-switch differences between the ELP maximum frame sizes allowed, a
connection was not allowed to a director set to CNT WAN extension mode.
Contact Computer Network Technologies for support. Exit MAP.
32
The director and attached device are performing a Fibre Channel link reset. This is
a transient state. Wait approximately 30 seconds and inspect port state and LED
behavior.
Did the link recover and resume operation?
NO
Go to
33
A link incident message displayed in the Link Incident Log or in the Link
Incident field of the Port Properties dialog box; or an event code 581, 582, 583,
584, 585, or 586 was observed at the console of an OSI or FICON server attached
to the director reporting the problem.
Clear the link incident for the port.
1. At the Hardware View, right-click the port. A menu displays.
2. Choose the Clear Link Incident Alert(s) option. The Clear Link Incident
Figure 33: Clear Link Incident Alert(s)
Director 2/140 Service Manual
YES
The director is operational. Exit MAP.
YES
The Fibre Channel link and director are operational. Exit MAP.
step
1.
Alert(s) dialog box displays, as shown in
Figure
33.
Diagnostics
131

Advertisement

Table of Contents
loading

Table of Contents