Diagnostics
16
Does a blinking red and yellow diamond overlay a UPM card graphic?
NO
17
A blinking red and yellow diamond overlays a control processor (CTP) card,
SBAR assembly, or fan module graphic.
A FRU failure is indicated. Go to
are found, go to
18
No colored attention indicator is associated with the icon representing the director
reporting the problem. Although the director is operational, a minor problem may
exist.
Double-click the icon representing the director reporting the problem. The
Hardware View displays. At the Hardware View:
Does a yellow triangle overlay a CTP card, SBAR assembly, or fan module
graphic?
YES
19
Beaconing is enabled for the FRU.
1. Consult the customer and next level of support to determine the reason FRU
52
YES
A UPM card failure is indicated. Go to
If no event codes are found, go to
Link Incident
"MAP 0500: FRU Failure
Inspect CTP cards, SBAR assemblies, and fan modules for a yellow triangle
that overlays the FRU graphic and indicates FRU beaconing is enabled.
Inspect UPM cards for a yellow triangle (attention indicator) that overlays the
UPM card graphic.
NO
Go to
step
20.
beaconing is enabled.
"MAP 0600: UPM Card Failure and
Analysis" on page 115. Exit MAP.
step 23
to obtain event codes. If no event codes
Analysis" on page 107. Exit MAP.
step 23
to obtain event codes.