20
The port connection conflicts with the configured port type. Either an expansion
port (E_Port) is incorrectly cabled to a Fibre Channel device or a fabric port
(F_Port) is incorrectly cabled to a fabric element (director or switch).
1. At the Hardware View for the selected director, choose Configure > Ports.
2. Use the vertical scroll bar as necessary to display the information row for the
3. Click the Type field and configure the port from the list box as follows:
4. Click Activate to save the configuration information and close the dialog box.
Did reconfiguring the port type solve the problem?
NO
Contact the next level of support. Exit MAP.
21
One of the following mode-mismatch conditions was detected and an ISL
connection is not allowed:
Reconfigure the director operating mode:
1. Ensure the director is set offline
Director 2/140 Service Manual
The Configure Ports dialog box displays.
port indicating an invalid attachment.
Choose fabric port (F_Port) if the port is cabled to a device (node).
Choose expansion port (E_Port) if the port is cabled to a fabric element
(director or switch) to form an ISL.
YES
The director is operational. Exit MAP.
The director is configured for operation in Open Fabric 1.0 mode and is
connected to a fabric element not configured to Open Fabric 1.0 mode.
The director is configured for operation in Open Fabric 1.0 mode and is
connected to a legacy HP director or switch at the incorrect Exchange Link
Parameter (ELP) revision level.
The director is configured for operation in Open Fabric 1.0 mode and is
connected to a non-HP switch at the incorrect ELP revision level.
The director is configured for operation in Open Fabric 1.0 mode and is
connected to a non-HP switch.
("Set Offline
State" on page 201).